Failure of the motor leads to the need to replace the central Orlando air conditioner. The fan needs to be removed and cleaned thoroughly on regular basis even if the motor is in working state.
(prHWY.com) March 6, 2013 - Orlando, FL -- Failure of the motor leads to the need to replace the central Orlando air conditioner. The fan needs to be removed and cleaned thoroughly on regular basis even if the motor is in working state. The air flow and effectiveness of the ventilation system of the
Orlando air conditioning unit are impeded by the deposits of air dirt and dust. Contamination of fan blades with bacteria and mold can threaten the health of the occupants of the building. The life of the central fan can be extended by replacing the filters on regular basis. The avoid the above-mentioned small problems into turning into big ones, one can perform Orlando air conditioning repair on their own.
The air handler of heating and cooling system has resemblance to a large drum and due to its size it is usually placed in the attic or outside. Before removing the motor the electrical circuit servicing the air conditioning system should be shut down so as to avoid any accidental shocks. Firstly, remove the motor assembly. Using a few bolts, the air handler assembly is attached to the outer casing. In order to free the assembly, cut the wires connected to the motor. Next, remove the motor casing from the air handler. The location of the mounting brackets of the motor which hold it in place should be noted down before removing the motor. Replacement motor does not generally include these brackets. The squirrel cages from motor axles are removed and cleaned. The number of squirrel cages seated on the motor axle varies from one to two depending on the motor axle. The vise, penetrating oil tap and rubber mallet are used to tap the cages off the axles.
On freeing the cages, they are cleaned thoroughly. The motor is then disassembled to examine whether only the bearings and brushes or the whole thing needs to be replaced. The new motor should be compatible with the equipment and installation should be done according the manufacturer's wiring diagram. Alternating current voltages are smoothened out by the capacitor of the blower motors and it advisable to replace it anytime the motor is serviced. Finally, reassemble the equipment to its original configuration and check. If the problem still persists, call Facility Pro Tech technicians for Orlando ac service and Orlando air conditioning repair to help you out.
###